Addressing HVAC Issues

HVAC sucioThe cleaning of the split and minisplit systems is vital for the equipment to operate correctly throughout the lifetime for which it was designed. by Jorge Gaitán*
 

The accumulation of contaminants and poor maintenance are the two main causes of inefficiency and failures of HVAC systems. Allowing dust to accumulate in coils and filters and delay in performing permanent maintenance can lead to higher prices on energy bills and service costs, accompanied by deterioration of buildings' internal air quality. To protect performance, split system components must be maintained twice a year. Below is a checklist for maintenance. Cleaning
Remove dust and dirt from the evaporator and condenser coils. A dirty coil reduces the equipment's ability to cool your building and causes the system to operate longer and this causes an increase in energy costs. External coils: Turn off the power supply of the unit. Remove all debris in the area and wash the coil with a hose. If the coil has a screen, wiring or blind and debris cannot be removed with the use of water, the top of the unit should be removed or the blind panels should be opened or removed. Ventilation components: They must be cleaned regularly and adjusted in such a way as to preserve proper airflow to achieve comfort and energy efficiency.  Problems with airflow can reduce the efficiency of the system by up to about 15%. Air filters: They should be checked once a month during the operating season and should be cleaned or replaced when necessary. Dirt filters can damage equipment and cause increased operation, which requires higher energy expenditure, and this can reduce the life of the equipment. Check the condensate drain lines and drain trays and perform the respective cleaning, if necessary. A clogged drain can cause high humidity and can lead to leakage and water damage. The heat exchangers, the furnace burner assembly and the ignition system should be checked, and the necessary cleaning should be carried out.
 


Verification
- Check thermostat settings to make sure the cooling system turns on or off at programmed temperatures. Check the power cycle of the equipment to ensure that the system power on is properly turned on or off. - Adjust the refrigerant charge if necessary. An inappropriate load causes the system to operate in a forced manner and use more energy; it also reduces the useful life of the equipment. Adjust electrical connections and measure the current consumption of all motors. - Check damage or wear of the entire control box, including contactors, relays, circuit boards, capacitors and other accessories. - Ducts should be checked to rule out leaks. - Check for possible damage, friction noise or vibration of the fan motor and blades. Visually check connection lines and coolant coils or leaks. - Make sure that the extraction system is properly connected to the furnace and make the necessary repairs to the damaged parts. - Check the heat exchanger to rule out any signs of corrosion. Replace it if necessary. Treatment
Adjust the ventilation speed for cooling. Measure pressure drops on the coil to determine the correct PCM (cubic feet per minute) of the ventilation, as set out in the unit's maintenance manual. In the ventilation of the transmission mechanism, check for any possible wear of belts and replace them annually or when necessary, and adjust the tension. If the unit is an older model that has no pre-lubrication or sealing, you must ensure that all moving parts are fully lubricated. Otherwise, friction can increase energy expenditure. While the system is in operation, its ignition should be monitored and the possible presence of abnormal noises or odors should be heard. Measure the external temperature of dry bulb and the internal temperature of dry and wet bulb throughout the coil. *Lennox Industries

No comments

• If you're already registered, please log in first. Your email will not be published.

Leave your comment

In reply to Some User
Real estate development increases efficiency and streamlines invoicing using an energy valve

Real estate development increases efficiency and streamlines invoicing using an energy valve

Mexico. This is Arboleda, a multipurpose development located in San Pedro Garza García, which has adopted a new approach to sustainable and efficient building management.

Solar generation hits new record: Global Energy

Solar generation hits new record: Global Energy

International. According to The Global Energy Association, global solar power generation increased by 30% in 2024, exceeding 2,000 terawatt-hours (TWh).

AHR Expo Orlando sets record numbers by surpassing 50,000 attendees

AHR Expo Orlando sets record numbers by surpassing 50,000 attendees

International. The AHR Expo took over Orlando for a week characterized by its agile pace of learning, reconnection, analysis and demonstration of all the novelties that are coming to the HVAC-R...

A refrigeration solution proves its effectiveness in the logistics sector

A refrigeration solution proves its effectiveness in the logistics sector

International. In the logistics sector, efficient refrigeration is no longer just a requirement but a matter of safety, quality and performance.

Italsan opens its new delegation in the Caribbean

Italsan opens its new delegation in the Caribbean

Dominican Republic. With the opening of its new headquarters located in the city of Bávaro, Italsan expands its presence in Latin America, where it already operates in Panama, Peru, Chile, Mexico...

Pharmaceutical cold chain: a model for efficient logistics in other industries

Pharmaceutical cold chain: a model for efficient logistics in other industries

International. The company Kryotec has highlighted that innovations in the pharmaceutical cold chain optimize traceability, monitoring and costs, guaranteeing safety and regulatory compliance in...

Air conditioning for premium shopping experiences: a success story in Guadalajara

Air conditioning for premium shopping experiences: a success story in Guadalajara

Mexico. Air conditioning in a store with a high influx of visitors represents a major challenge: to maintain thermal comfort without generating annoying drafts, to guarantee proper air circulation...

Frascold unveils its advances in efficiency and sustainability

Frascold unveils its advances in efficiency and sustainability

International. Frascold, whose solutions are distributed in 13 countries in Latin America and the United States, has been awarded UNI EN ISO 14001:2015 certification for its environmental...

Samsung Mexico inaugurates first training center specialized in air conditioning systems

Samsung Mexico inaugurates first training center specialized in air conditioning systems

Mexico. Samsung opened this space for customers, employees and business partners, aimed at training, service and support, while strengthening the knowledge of professionals in air conditioning...

Eurovent updates its Recommendation for evaporative cooling equipment

Eurovent updates its Recommendation for evaporative cooling equipment

International. Eurovent has published a second version of its Recommendation 9/12 on the performance efficiency standard for evaporative cooling equipment.

Free Subscription
SUBSCRIBE TO OUR NEWSLETTER
DO YOU NEED A SERVICE OR PRODUCT QUOTE?
LASTEST INTERVIEWS
SITE SPONSORS










LASTEST NEWSLETTER
Ultimo Info-Boletin